Alfa Laval T56-FMC Plate Heat Exchanger.

Print   Print this page      Email   Email to a friend

Application
Heating of water or CIP (cleaning in place) solutions by means of
steam. General heating and cooling duties.
Working Principles
Channels are formed between the plates and the corner ports are
arranged so that the two media flow through alternate channels.
The heat is transferred through the plate between the channels, and
complete counter-current flow is created for highest possible efficiency.
The corrugation of the plates provides the passage between the
plates, supports each plate against the adjacent one and enhances
the turbulence, resulting in efficient heat transfer.
Standard design
The plate heat exchanger consists of a pack of corrugated metal
plates with portholes for the passage of the two fluids between which
heat transfer will take place.
The plate pack is assembled between a fixed frame plate and a
movable pressure plate and compressed by tightening bolts. The
plates are fitted with a gasket which seals the interplate channel and
directs the fluids into alternate channels. The number of plates is
determined by the flow rate, physical properties of the fluids, pressure
drop and temperature program. The plate corrugations promote fluid
turbulence and support the plates against differential pressure.
The plate and the pressure plate are fixed between upper bar and
lower bar, which again is fixed to a support column.
Connections are located in the frame plate or, if either or both fluids
make more than a single pass within the unit, in the frame and
pressure plate.

Typical capacities
Liquid flow rate
Up to 20 kg/s, depending on media, permitted pressure drop and
temperature program.
Water heating by steam
200 - 1,800 kW
Frame type
FMC
Plate types
TS6M
Standard Materials
Frame plate
Frame and pressure plate in solid stainless steel AISI 316L
Nozzles
Stainless steel AISI 316L
Plates
Stainless steel AISI 316
Gaskets
Nitrile, EPDM or HeatSeal F™
Connections
Flange 65 mm DIN 2501 PN10
Sanitary connections 76 mm. DIN, SMS, Tri-Clamp, B.S./RJT and
IDF/ISO male parts.
Technical Data
Mechanical design pressure (g) / Temperature
FMC 1.0 Mpa/175C
Maximum heat transfer surface
13 m2 (140 sq. ft)
Particulars required for quotation
- Flow rates or heat load
- Temperature program
- Physical properties of liquids in question (if not water)
- Desired working pressure
- Maximum permitted pressure drop
- Available steam pressure